Location:Valve testingProductCompetitiveYFC(intelligent type)Hydraulic Valve Testing Machine

YFC(intelligent type)Hydraulic Valve Testing Machine
Introduction

Performance feature

◎Is suitable for through flange valve sealing pressure and valve body intensity pressure performance test.

◎The impact method adopts the flange end face seal, holds and presses the claw clip valve flange reverse side to carry out the working experiment and the test result has no the influence of outside force.

◎Valve can turn 90 degree working in testing course, especial suitable for property experiments of gas seal.

◎Equip with the high and low pressure water pump pressure supply device in system, the test medium circulating storage use.

◎Pressure trial medium is water, air and kerosene, arbitrary option by users.

◎Equip with the pressure test safe protective device.

◎You can select the intelligent detection data control system,air pressure boosting device.

1 Removal frame

7 Left decompression switch

13 Left low pressure meter

19 Digital clock

2 Sealing disk

8 Left water inlet switch

14 Gas main pressure meter

20 Time relay

3 Press piston rod

9 Pressure contrast table 

15 Oil pump pressure meter

21 Light and sound

alarm

4 Pressed paw

10 Right water inlet switch

16 Electric point joint pressure table

22 Low pressure

water pump

5 Main switch

11 Right decompression

switch

17 Right low pressure meter

23 High pressure

water pump

6 Electric button board

12 Left boosting meter

18 Right boosting meter

24 Air pressure switch

Contrast table of pressure needed of YFC-100 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

1/2

15

3/4

20

1

25

11/4

32

11/2

40

2

50

21/2

65

3

80

 

 

 

 

4

100

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-200 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

150

300

400

600

900

1500

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

2

50

21/2

65

3

80

4

100

5

125

6

150

8

200

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-300 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

3

80

4

100

5

125

 

 

6

150

 

 

 

 

8

200

 

 

 

 

 

 

10

250

 

 

 

 

 

 

 

 

12

300

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-400 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

6

150

 

 

 

 

8

200

 

 

 

 

10

250

 

 

 

 

 

 

12

300

 

 

 

 

 

 

 

 

14

350

 

 

 

 

 

 

 

 

 

 

16

400

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-500 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

10

250

 

 

 

 

 

 

12

300

 

 

 

 

 

 

 

 

14

350

 

 

 

 

 

 

 

 

 

 

16

400

 

 

 

 

 

 

 

 

 

 

18

450

 

 

 

 

 

 

 

 

 

 

 

 

20

500

 

 

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-600 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

12

300

 

 

 

 

 

 

14

350

 

 

 

 

 

 

 

 

16

400

 

 

 

 

 

 

 

 

 

 

18

450

 

 

 

 

 

 

 

 

 

 

20

500

 

 

 

 

 

 

 

 

 

 

 

 

24

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-800 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

16

400

 

 

 

 

 

 

 

 

18

450

 

 

 

 

 

 

 

 

20

500

 

 

 

 

 

 

 

 

 

 

24

600

 

 

 

 

 

 

 

 

 

 

28

700

 

 

 

 

 

 

 

 

 

 

 

 

32

800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-1000 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

20

500

 

 

 

 

 

 

24

600

 

 

 

 

 

 

 

 

28

700

 

 

 

 

 

 

 

 

 

 

32

800

 

 

 

 

 

 

 

 

 

 

36

900

 

 

 

 

 

 

 

 

 

 

 

 

40

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).

Contrast table of pressure needed of YFC-1200 model


Nominal

diameter

MPa  ∕  Class

1.6

2.5

4.0

6.4

10.0

16.0

20.0

25.0

32.0

 

150

300

400

600

900

 

1500

 

Pressure of hydraulic system      (pressurization)   MPa

in

DN

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

PN

PS

24

600

 

 

 

 

 

 

 

 

 

 

28

700

 

 

 

 

 

 

 

 

 

 

 

 

32

800

 

 

 

 

 

 

 

 

 

 

 

 

36

900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:  1. During valve test, PN (seal test), PS is valve (strength test).