Location:Valve testingProductCompetitiveYFC(intelligent type)Hydraulic Valve Testing Machine
Introduction


Performance feature
◎Is suitable for through flange valve sealing pressure and valve body intensity pressure performance test.
◎The impact method adopts the flange end face seal, holds and presses the claw clip valve flange reverse side to carry out the working experiment and the test result has no the influence of outside force.
◎Valve can turn 90 degree working in testing course, especial suitable for property experiments of gas seal.
◎Equip with the high and low pressure water pump pressure supply device in system, the test medium circulating storage use.
◎Pressure trial medium is water, air and kerosene, arbitrary option by users.
◎Equip with the pressure test safe protective device.
◎You can select the intelligent detection data control system,air pressure boosting device.
1 Removal frame |
7 Left decompression switch |
13 Left low pressure meter |
19 Digital clock |
2 Sealing disk |
8 Left water inlet switch |
14 Gas main pressure meter |
20 Time relay |
3 Press piston rod |
9 Pressure contrast table |
15 Oil pump pressure meter |
21 Light and sound alarm |
4 Pressed paw |
10 Right water inlet switch |
16 Electric point joint pressure table |
22 Low pressure water pump |
5 Main switch |
11 Right decompression switch |
17 Right low pressure meter |
23 High pressure water pump |
6 Electric button board |
12 Left boosting meter |
18 Right boosting meter |
24 Air pressure switch |

Contrast table of pressure needed of YFC-100 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN | PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
1/2 |
15 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
3/4 |
20 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
1 |
25 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
11/4 |
32 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
11/2 |
40 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
2 |
50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
21/2 |
65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
3 |
80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
4 |
100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-200 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
150 |
300 |
400 |
600 |
900 |
1500 |
||||||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
2 |
50 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
21/2 |
65 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
3 |
80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4 |
100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||
5 |
125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||
6 |
150 |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||||
8 |
200 |
● |
● |
● |
● |
● |
● |
● |
● |
||||||||||
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-300 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
3 |
80 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
4 |
100 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
5 |
125 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
6 |
150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
8 |
200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
10 |
250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
12 |
300 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-400 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
6 |
150 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
8 |
200 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
10 |
250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
12 |
300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
14 |
350 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
16 |
400 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-500 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
10 |
250 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
12 |
300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
14 |
350 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
16 |
400 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
18 |
450 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
20 |
500 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-600 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
12 |
300 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
14 |
350 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
16 |
400 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
18 |
450 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
20 |
500 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
24 |
600 |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-800 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
16 |
400 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
18 |
450 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
20 |
500 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
24 |
600 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
28 |
700 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
32 |
800 |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-1000 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
20 |
500 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
24 |
600 |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
28 |
700 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
32 |
800 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
36 |
900 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
40 |
1000 |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||
Contrast table of pressure needed of YFC-1200 model
diameter |
MPa ∕ Class |
||||||||||||||||||
1.6 |
2.5 |
4.0 |
6.4 |
10.0 |
16.0 |
20.0 |
25.0 |
32.0 |
|||||||||||
|
150 |
300 |
400 |
600 |
900 |
|
1500 |
|
|||||||||||
Pressure of hydraulic system (pressurization) MPa |
|||||||||||||||||||
in |
DN |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
PN |
PS |
24 |
600 |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
28 |
700 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
32 |
800 |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
36 |
900 |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 |
1000 |
● |
● |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48 |
1200 |
● |
● |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: 1. During valve test, PN (seal test), PS is valve (strength test). |
|||||||||||||||||||